Top
products
W2 Industrial Services Hub
VOC Monitoring System and VOC Dehumidifier System
Waste discharge containing a high concentration of VOCs can cause fires in the sewer pipeline and downstream water reclamation plants in Singapore. The W2 VOC Monitoring & Control System is designed to detect and monitor the last inspection chamber of the trade premises before the discharge of industrial used water or trade effluent into the public sewer, and sends an alert to the user if there was an illegal discharge.

The W2 VOC Monitoring & Control System is environmentally-sealed and comes with an integrated revolutionary fixed VOC detector that provides you the reliability, accuracy and results you can trust in your industrial application. With accurate gas monitoring from the detector, we also provide an industrial IOT telemetry that is reliable for collecting, processing and transferring data in the integrated system. This includes sending out an SMS alert to the user when high values of VOC are detected.

Our W2000 DH – a thermoelectric dehumidifier unit, can complement the VOC monitoring system and can effectively remove moisture from the sample gas.
 
VOC Monitoring System
W2000 Series VOC Monitoring & Control System
W2000 Series VOC Monitoring & Control System
Features & Benefits
  • Rapid, accurate detection of VOCs and eliminates false readings found with other competing PID technology
  • Typhoon Technology prevents condensation forming within the PID
  • Selectable range (0.001 10ppm, 0.01 50ppm, 0.1 1000ppm or 1 3000ppm)
  • Seamless integration of IIoT Solutions between Node RED, the intelligent gateway and the IOT telemetry. This provides an ideal platform for collecting, processing and transferring of data and is suitable for use at numerous industrial environments.
  • Industrial peristaltic pump with low shear, gentle handling, and without impellors, vanes, lobes or valves in the fluid path
  • Sample preconditioning air filtration system with optimum performance
  • Environmentally sealed to IP65
  • Simple installation and servicing
Specifications: - TECHNICAL SPECIFICATION
  • Sensor (PID): 10.6 eV lamp with Ion Science’s Fence Electrode, anti-contamination and Typhoon technology
  • Ingress Protection Rating: IP65
  • Power: 110/230 Vac
  • Range: 0.001-10 ppm, 0.01-50 ppm, 0.1-1000 ppm and 1-3000ppm
  • Response: Detection time T90 less than 10 secs
  • Accuracy: +/- 5 % at calibration point
  • Measuring Interval: 1 second
  • Operating Humidity: 0 – 100 RH% (condensing)
  • Operating Temperature: -20°C to + 50°C
W2 VOC Dehumidifier System
W2000 Series VOC Monitoring & Control System
W2000-DH
W2000-DH is the thermoelectric dehumidifier unit for use with our VOC monitoring system. It utilizes a high-performance semiconductor cooling plate as a heat sink, and is combined with a high precision PID temperature control system that can effectively remove moisture from the sample gas.
Specifications:
  • Temperature Setting: 1 ℃
  • Setting Accuracy: 1 ℃ ± 0.5 ℃
  • Control Precision: ± 0.1 ℃
  • Operating temperature: 0-40 ℃
  • Max. inlet gas temperature: 80 ℃
  • Max. gas humidity: 85% RH
  • Temperature Sensor: PT100 Platinum RTD
  • Temperature Control Point: 1 ℃
  • Short-term fluctuations: ± 0.1 ℃
  • Material: Stainless steel 304
  • Max. Working Pressure: 0.2 MPa
  • Operating Temperature: 2 ~ 45 ℃
  • Operating Humidity: 95% RH (Non-condensing)
  • Dimensions: W185 * D125 * H122 (mm)
  • Weight: 2.0 KG
  • Working Principle: Thermoelectric cooler
  • Power Supply: AC-100V ~ 220V ± 10%; 50 / 60Hz ± 3%
  • (EU) Directives: RoHS Compliance